-40%
24H Dynamic ECG Holter Monitor EKG System Machine,pacemaker Analyzer,PC Software
$ 157.87
- Description
- Size Guide
Description
ambulatory blood pressure monitorTLC9803 24Hours 3 Channel 12 Leads ECG Holter with PC Software
Description
Brief Introduction
TLC9803 Dynamic ECG Systems adapts 3-lead system defined by our company, can record continuously ECG waves for 24h, and analyses waves with PC software. It is applicable in hospital and community medical establishment.
Recorder Features
With advanced design and technology, the recorder can work stably, dependably and durably.
Be provided with the capability of anti-jamming and aseismatic.
Small volume with OLED screen. The resolution is 160*128.
Be provided with functions of waveform preview, record review and event marking.
Accurate record of the start time of the data sampled owing to the real time clock of itself.
Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data.
The maximum capability can be 2GB, so the original data can be saved perfectly by no compression.
The average review time of single case can be less than 40 seconds by using interface of USB 2.0.
Record waveform details inextenso by the design of high precision and sampling frequency.
Record the state of pacemaker exactly by higher sampling frequency.
The Features of Software
Quick and accurate analysis system.
The 3-lead synchro analysis, to find accurate, QRS search can be accurate and no distortion.
There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms.
Flexible analysis channel selection function, can choose any channel as the mainly analysis the channel.
Flexible atrial fibrillation analysis,so that physicians can use full,segmented automatic,manual analysis of atrial fibrillation,make the analysis more quickly and accurately.
Powerful pacemaker analysis, on the AAI,VVI,DDD etc. all pacemaker analysis.
Many pacing modules have been added.
Fast review analysis function, can be any period of time the review single lead or all leads electrocardiogram.
Analysis of heard rate variability with short-range 5 minutes and long-range 1 hour and 24 hours analysis of heart rate variability.
One-stop printing operation, report printing process is convenient and quick.
Perfect function of case management.
Advanced ST segment analysis and myocardial ischemia total load, can for the ST abnormal analysis according to the whole and event, make the doctor can comprehensive judgment myocardial ischemia.
Unique "Sleep breath pause syndrome analysis" analysis can predict Sleep breath pause risk.
"HRT" analysis can predict the risk of death in patients with myocardial infarction.
"T Wave alternation" analysis is an important index to predict malignant arrhythmia and sudden cardiac death.
Standard
Number of channels: 3 channels
Sampling accuracy:12Bit
Record time: 24 h
Power: 2 AA size batteries
Interface: USB2.0
Scale voltage: 1mV±5%
Standard Sensitivity: 10mm/mV±5%
Noise level: ≤30μV
CMRR: ≥60dB
Low-frequency characteristics: Time constant≥3.2s
Scan speed: 25mm/s±5%
Enduring polarization voltage: ±300mV DC polarization voltage,sensitivity shift≤±10%
Least measure signal: 50 µV p-p
Product safety type: Type B (Internally powered)
Accessories
3-lead ECG lead wires (1 set)
ECG electrode 1 bag(20 per bag)
USB data line(1)
Disk(1)
Bag(1)
User manual(1)
TLC5000 24 Hours 12 Channel ECG Holter 12 Leads Monitor+PC Software
Description
Model:
TLC5000 12 Channel ECG Holter Monitor
Brief Introduction
TLC5000 Dynamic ECG Systems adapts international standard 12-lead system, can record continuously ECG waves for 24h, and analyses waves with PC software. It is applicable in hospital and community medical establishment.
Recorder Features
With advanced design and technology, the recorder can work stably, dependably and durably.
Be provided with the capability of anti-jamming and aseismatic.
Small volume with OLED screen. The resolution is 160*128.
Be provided with functions of waveform preview, record review and event marking.
Accurate record of the start time of the data sampled owing to the real time clock of itself.
Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data.
The maximum capability can be 2GB, so the original data can be saved perfectly by no compression.
The average review time of single case can be less than 40 seconds by using interface of USB 2.0.
Record waveform details inextenso by the design of high precision and sampling frequency.
Record the state of pacemaker exactly by higher sampling frequency.
International standard of 12 leads. Record 24-hour DECG with the same standard of the ECG.
The features of software
Quick and accurate analysis system.
The 12-leads synchro analysis, to find accurate,QRS search can be accurate and no distortion.
There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms.
Flexible analysis channel selection function,can choose any channel as the mainly analysis the channel.
Flexible atrial fibrillation analysis ,so that physicians can use full,segmented automatic manual analysis of atrial fibrillation,make the analysis more quickly and accurately.
Powerful pacemaker analysis,on the AAI,VVI,DDD etc. all pacemaker analysis.
Many pacing modules have been added.
Fast review analysis function,can be any period of time the review single lead or all leads electrocardiogram.
Analysis of heard rate variability with short-range 5 minutes and long-range 1 hour and 24 hours analysis of heart rate variability.
Qne-stop printing operation,report printing process is convenient and quick.
Perfect function of case management.
Advanced ST segment analysis and myocardial ischemia total load,can for the ST abnormal analysis according to the whole and event,make the doctor can comprehensive judgment myocardial ischemia.
Unique "Sleep breath pause syndrome analysis" analysis can predict Sleep breath pause risk.
"HRT" analysis can predict the risk of death in patients with myocardial infarction.
"T Wave alternation" analysis is an important index to predict malignant arrhythmia and sudden cardiac death.
With QT discrete degree analysis,ventricular late potential analysis,vector ecg analysis,time vector analysis and so on,many kinds of additional analysis function,make analysis report more reference value.
Standard
Number of channels: 12 channels;
Sampling accuracy:12Bit
Record time : 24 h;
Power: 2 AA size batteries;
Interface: USB2.0;
Scale voltage:1mV±5%;
Standard Sensitivity:10mm/mV±5%;
Noise level:≤30μV;
CMRR:≥60dB;
Low-frequency characteristics : Time constant≥3.2s;
Scan speed:25mm/s±5%;
Enduring polarization voltage:±300mV DC polarization voltage,sensitivity shift≤±10%;
Least measure signal : 50 µV p-p;
Product safety type : Type B (Internally powered).
Accessories
12-lead ECG lead wires (1 set)
ECG electrode 1 bag(20 per bag)
USB data line(1)
Disk(1)
Bag(1)
User manual(1)
Softdog
Physical characteristic
Dimension:111mm(L) * 60mm(W) *25mm(H)
Weight:About 105g(without battery)
TLC6000 48Hours 12 Channel 12 Leads ECG Holter with PC Software
Introduction
Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 48-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.
Function
1)Adopt 12-lead system of international standard, continuously record ECG waveform up to 48-hour.
2)Sync analysis for 12-lead, and any channels can be selected as the main analysis channel, which ensures that QRS waveform can be found accurately, and no distortion.
3)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
4)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
5)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
6)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
7)With analysis functions for 5-minute, 1-hour and whole heart rate variability.
8)One-key print, convenient and fast to print the reports.
9)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
10)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death.
11)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.
Performance
Lead: standard 12-lead
Power supply: one “AAA” battery
Calibration voltage: 1mV±5%
Noise level: ≤30µV p-p
CMRR: ≥60dB
Frequency response: 10Hz as benchmark, 0.5Hz~55Hz: -3dB
Low-frequency characteristics: ≥3.2s
Scan speed: 25mm/s±5%
Polarizing voltage: ±300mV, sensitivity: ≤±10%
Minimum measure signal: 50 µV p-p
Accessories
Lead cable (1 set)
ECG electrode (1 bag)
USB cable(1)
Disk(1)
Bag(1)
User manual(1)
Physical characteristic
Recorder dimension: 80.5mm(L) × 59.5mm(W) × 22mm(H)
Weight: about 61.5g(without batteries)
Payment
We accept Paypal Payment,Bank Transfer.
Shipping
Clearance: we will ship your item to your Ebay confirmed address.Buyers' responsibility to pay duties,taxes and other extra charges by the government in your country.All items will be shipped within 2 business days by E-package,Airmail shipping.According to shipping method,items will be delivered within 7-35 business days.
Terms of Sale
Buy safe Products
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item. If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K Approved.
About Us
Contec Medical Systems Co.,Ltd; 20 Years manufacturer,we have stock in USA and China.
Contact Us
Please contact us through eBay Message, we are on line to reply your message within 24 hours.
Wha
tsapp/Wechat/Mobile:+86 18716007715
,
[email protected]
.
We only have the English Manual in the standard package, If you need any other language Manual, please contact us freely